WARNReviewer 1· 85% conf
Methods are described in adequate detail, but the paper lacks a reporting guideline, pre-registration (not applicable), and does not discuss limitations in depth.
Evidence
direct quote[Methods section]
“Firstly, the copper substrate was ultrasonically cleaned with acetone (CH₃COCH₃) for 1 min to remove the oil, and then washed with dilute sulphuric acid (H₂SO₄) with a volume fraction of 10% for 30 s, and then activated with palladium chloride (PdCl₂) for 1 min.”direct quote[Results, section 3.4]
“the average shear strength of the soldering joints is up to 35 MPa, which is still far from the average shear strength of 50 MPa of commercial solder.”direct quote[Conclusion]
“This low-temperature soldering technology is expected to become a new soldering method in high-density chip packaging.”WARNReviewer 2· 85% conf
Methods are described in reasonable detail, limitations are discussed, conclusions are proportional, and funding/COI are reported. However, no reporting guideline is followed, and it is unclear whether all outcomes (e.g., microstructure outcomes beyond SEM/TEM) were pre-specified and reported.
Evidence
direct quote[Section 2 (Experimental)]
“The lead frame material C194 copper alloy was used as the substrate ... the copper substrate was ultrasonically cleaned with acetone ... the electrolyte consisted of analytical pure solution CuSO4·5H2O (0.04 mol/L) ...”direct quote[Results, Section 3.4, and Conclusion]
“the average shear strength of the soldering joints is up to 35 MPa, which is still far from the average shear strength of 50 MPa of commercial solder.”direct quote[Declaration section]
“Funding statement This study was funded by the Guangzhou Zengcheng District Science and Technology Planning Project (NO:2021ZCMS11). Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.”PASSReviewer 3· 85% conf
The paper provides detailed methods, reports all outcomes, gives proportional conclusions, and includes funding/COI statements, but lacks a discussion of limitations.
Evidence
direct quote[Section 2 Experiment]
“The lead frame material C194 copper alloy was used as the substrate (20 mm × 20 mm × 0.15 mm), and a superhydrophobic copper microlayer was electrochemically deposited on the copper substrate.”direct quote[Funding statement and Declaration of competing interest]
“This study was funded by the Guangzhou Zengcheng District Science and Technology Planning Project (NO:2021ZCMS11).”absence[Section 4 Conclusion]
Limitations of the study are not discussed.